Return temperature raising set EUROMIX SMARTCONTROL
PS 103MSC - PS 107MSC
It is used to increase the return temperature of the boiler. With the Smartcontrol motorized controller, it ensures optimal system operation.
Components:
  • Ball shut-off valves
  • Check valve
  • Circulation pump
  • Three-way mixing valve
  • Motorized actuator with Smartcontrol regulator
Category:
  • DOCUMENTATION
  • DIMENSIONS
  • USAGE
  • QUALITY
  • TECHNICAL DATA
  • INSTALLATION
ART. IDENT DN EAN PUMP kW L [mm]  L1 [mm]  L2 [mm]  L3 [mm]  L4 [mm]  G* [in]  G1* [in] G2** [in] R** [in]  H [mm] H1 [mm] W [mm]
PS 103MSC 1237145 20 3838963242017 Wilo Yonos PARA RS 25/6 RKA 180 20 426 180 13 11 - 3/4" 3/4" -   148 114 60
PS 104MSC 1247145 25 3838963242024 Wilo Yonos PARA RS 25/6 RKA 180 35 465 180 15 16 - 1"  1" -   158 124 60
PS 105MSC 1257145 32 3838963242048 Wilo Yonos PARA RS 25/6 RKA 180 60 508 180 18,8 18 - 1 1/4" 1 1/4" -   162 128 60
PS 106MSC 1267144 40 3838963242055 Wilo Stratos PARA 30/1-12 100 689 180 21,4 22 15 1 1/2" 1 1/2"  1 3/4" 1 1/2" 257 201 136
PS 107MSC 1267145 40 3838963242062 Wilo Yonos MAXO 40/0,5-12 150 754 250 21,4 17 - 1 1/2" 1 1/2"  -   390 315 136
The HERZ EUROMIX SMARTCONTROL- Return temperature set is used in heating systems in industrial and household areas. With connection of the boiler and the buffer tank, it is necessary to install the return temperature set for protection of the boiler protecting against too low back flow temperature entering the boiler.
Low temperature of boiler backflow should be avoided because of two reasons:
• It prevents condensation and prolongs boiler life because the return to the boiler has the correct temperature.
• Provides the necessary operating temperature of the boiler and thus the proper operation of the heating system and filling of the buffer tank
The advantage of the HERZ EUROMIX SMARTCONTROL – return temperature set compared to other sets is that the set includes a HERZ SMARTCONTROL motor drive, which continuously monitors the return water temperature and energy source with the provided sensors. Using the collected data, it ensures optimal regulation and appropriate adjustment of the return flow to the boiler. The entire system features a “Plug&Play” installation method.



T1 – temperature sensor for cold water return
T2 – temperature sensor for the heat source

T1 (included in set)
The temperature sensor T1 is installed on the return line, behind the circulation pump. It measures the temperature of the cold water before entering the boiler. The cable length is 1 meter.


T2 (included in set)The temperature sensor T2 needs to be inserted at the location of the heat source and measures the temperature of the heat source. The cable length is 3 meters. Heat source can be:
- BUFFER
- BOILER


SCHUKO PLUG (included in set)
The HERZ Smartcontrol motorized smart controller is equipped with a Schuko connector, making the entire system "Plug & Play." Thanks to the Schuko plug, the smart controller can be easily connected to standard European electrical outlets, ensuring a quick and hasslefree installation process. This feature significantly simplifies the setup, as no complex wiring or additional components are required.




Operating data:
Operating pressure: 10 bar (without pump), with pump see pump characteristics
Min. operating pressure: 0 °C (water 0,5 °C)
Max. operating pressure: 110 °C
Max. short-term temperature load: 120 °C

Medium:
Heating water according to ÖNORM H5195 or VDI-Standard 2035. The use of ethylene or propylene glycol in a mixing ratio 25- 50% is allowed. EPDM gaskets can be affected by mineral oils lubricants and thus lead to failure of the EPDM seals. Please refer to manufacturers documentation when using ethylene glycol and propylene glycol products for frost and corrosion protection




Components:
  1. Ball valve
  2. Check valve
  3. Circulation pump
  4. Ball valve
  5. Smartcontrol motor controller (1 4522 00)
  6. 3-way mixing valve (1 2137 0X)